15% Discount on Toy and Gift Category with Coupon blackfriday10 - Free Shipping Over 99.00 Thru Dec. 1st

Combined Logging Bench Meter GLP pH/mV/EC/TDS/NaCl/C

$699.95

Be the first to review this product

Overview:

Combined Logging Bench Meter GLP pH/mV/EC/TDS/NaCl/C

Availability: In Stock

Details

Mi180 measures 6 different parameters: pH, ORP, EC, TDS, percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where verywide differences in pH can be found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitableto the tested sample. All measurements can be temperature compensated at 20 or 25C and the compensation coefficient is selectable by the user.
The automatic temperature compesnsation can also be disabled for measuring the actual conductivity value. The stability indicatoron the LCD ensures accuracy. Conducivity readings are performed with the 4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.
Specifications:
Range -2.00 to 16.00 pH; -2.000 to 16.000 pH
699.9 mV; 2000 mV
0.00 to 29.99 S/cm; 30.0 299.9 S/cm; 300 to 2999 S/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm;
up to 500.0 mS/cm actual conductivity (uncompensated EC*)
0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/l (ppt);
15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS (with .080 factor)
0.0 to 400.0%
-20.0 to 120.0C / -4.0 to 248.0F
Resolution 0.01 pH; 0.001pH
0.1mV; 1mV
0.01 S/cm; 0.1 S/cm; 1.0 S/cm; 0.01 mS/cm; 0.1 mS/cm
0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/l; 0.1 g/l
0.1%
0.1C / 0.1F
Accuracy 0.01 pH; 0.002 pH
0.2 mV; 1 mV
1% of reading (0.05 S/cm or 1 digit)
1% of reading (0.03 ppm or 1 digit)
1% of reading
0.4% / 08F
Rel mV offset 2000 mV
Calibration 1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
1 point slope calibration with 6 memorized solutions available: (84 S/cm, 1413 S/cm, 5.00 mS/cm,
12.88 S/cm, 111.mS/cm)
1 point, with MA9066 calibration solution
2 point, at 0 and 50C / 32 and 122F
Temperature Compensation Automatic or manual , from -20.0 to 120.0C / -40. to 248.0F
Temperature Coefficient Selectable from 0.00 to 6.00% / C (EC and TDS only)
pH Electrodes Probe MA917B/1 (included)
EC Probe MA831R (included)
TDS Factor 0.40 to 0.80 (default value is 0.50)
Log on demand (samples) 50 on each range (pH, mV, EC, TDS, NaCL)
GLP Last pH, EC, NaCL calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 to 50C / 32 to 122F; max RH 95%
Input Impedance 230 x 160 x 95mm
Power supply 10^12 OHM
Dimensions 230 x 160 x 95mm
Weight .09 kg

FULL 2 Year Manufacturers Warranty with serial number registration.

Additional Information

SKU MILMI180US
Lead Time No
Product Warnings Caution - To be used under Adult Supervision. Proper Laboratory Safety Procedures Should Always be Followed!, Caution - Product contains glass and may break if handled improperly. Handle with care.
Country of Origin No
Available for Gift Wrap No

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Warnings:
  • Caution - To be used under Adult Supervision. Proper Laboratory Safety Procedures Should Always be Followed!
  • Caution - Product contains glass and may break if handled improperly. Handle with care.