MC125 pH/ORP Controller w/dual Set Points

MC125 pH/ORP Controller w/dual Set Points

Overview

pH Set Point: 4-8pH ORP Set Point: -200 to 600mV

Warnings

MC125 pH/ORP Controller w/dual Set Points

Regular price $318.00 In Stock
Reviews Read Reviews

Overview

pH Set Point: 4-8pH ORP Set Point: -200 to 600mV

Warnings

Product Details

The MC125 is the successer to the popular, but aging SMS line of controllers.  This pH/ORP controller features dual set points with adjustable knobs.  The pH set point is between 4 to 8 pH, while the ORP set point is between -200 to 600mV.  Solenoid valves or pumps can be attached to the controller to automatically dose the environment with CO2 and ozone, which makes it perfect where 25-hour maintenance is needed.

Power is supplied to the unit by way of a 12V adapter, so there's no need to worry about failing batteries.  Each unit also comes with a mounting kit, probe, probe holder and a starter calibration solution.

MC125 Specifications
Range 0.00 to 14.00pH & +/-1000mV (ORP)
Resolution 0.01pH & 1mV +/- (ORP)
Accuracy @25C +/-0.2pH & +/-5mV (ORP)
pH Set Point 4 to 8 pH
ORP Set Point -200 to 600mV
pH Alarm Alerts when above/below user-selected set point
ORP Alarm Alerts when above/below user-selected set point
pH Output Power Socket Active when higher/lower than set point
ORP Output Power Socket Active when higher/lower than set point (5A max)
pH Electrode MA911B/2 (included)
ORP Electrode MA921B/2 (included)
Environment 0 to 50C (32 to 122F); max RH 95%
Power Supply 12 VDC power adapter (included)
Power Driver 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz

Additional Information

SKU

MILMC125

Weight

2.0 lb

​ ​